DLR: airborne sound insulation
DLR is the single-number rating of a barrier's airborne sound insulation, in decibels. The barrier is measured in a laboratory between two reverberant rooms, band by band from 100Hz to 5kHz, under BS EN 1793-2. The band values are then weighted against a reference noise spectrum to give one number.
For road traffic, the weighting uses the normalised traffic noise spectrum of BS EN 1793-3. For railways, BS EN 16272-2 uses the rail spectrum of BS EN 16272-3-1, so the same barrier can have different road and rail ratings. NoiseBloc® Premium TGV is DLR 26dB road and 28dB rail.
DLα: sound absorption
DLα rates how much sound the face of the barrier absorbs instead of reflecting it, measured to BS EN 1793-1. It matters where reflected noise is a problem: barriers on both sides of a road or railway, homes or buildings opposite, or plant enclosed on several sides. NoiseBloc® Eco absorptive has a declared DLα of 9dB (manufacturer's data).
What happened to Category B3?
Earlier editions of BS EN 1793-2 grouped DLR results into categories: B0 (not determined), B1 (below 15dB), B2 (15dB to 24dB) and B3 (above 24dB). Absorption had a similar A scale. The current editions report the values without categories, but many specifications and competitor datasheets still quote them.
If a specification asks for Category B3, the clearest reading is a DLR above 24dB. Premium TGV's road DLR of 26dB exceeds that threshold. When writing a new specification, state the DLR value and the standard edition instead.
Laboratory and in-situ ratings
Some products also quote ratings measured on installed barriers, under BS EN 1793-5 for reflection and BS EN 1793-6 for sound insulation. They are measured differently and should not be compared directly with laboratory DLR values.
Comparing products fairly
- Same standard and edition: BS EN 1793-2:2018 results are not directly comparable with tests to older editions or different methods.
- Road or rail: check which rating is quoted.
- Tested build equals supplied build: the board sizes, joints and fixings tested should match what arrives on site.
- Surface mass in kg/m², not density in kg/m³.
- Single values, not “up to”: ask for the rating of the system you will actually install, with band data.
What to write in a specification
A clear performance clause might read: airborne sound insulation DLR not less than 25dB to BS EN 1793-2:2018, tested by a UKAS-accredited laboratory, with one-third octave band data provided. Add a rail rating to BS EN 16272-2:2023 where trains are the source, and DLα to BS EN 1793-1 where an absorptive face is needed. Our technical library has full NoiseBloc® clauses and equivalence criteria.