Start with the line of sight
Sound reaches a listener behind a barrier mainly by bending over the top edge. A barrier only starts to help once it blocks the line of sight between the noise source and the receiver, and each extra bit of height makes the sound travel further over the top, which reduces it further.
As a broad guide, a barrier that just breaks the line of sight gives around 5dB of reduction. A well-designed barrier can give around 10dB to 15dB, and about 20dB is a practical upper limit for a single barrier. A 10dB reduction sounds roughly half as loud.
Position matters as much as height
A barrier works best close to the noise source or close to the people it protects, because that bends the sound path most sharply. A barrier halfway between the two needs to be taller for the same effect. That is why plant screens are often built tight around the equipment, and garden fences sit on the plot boundary nearest the road.
Make it long enough
Sound also travels around the ends of a barrier. It should extend well beyond the area it protects, and the ends should close against buildings, walls or returns. A short barrier with open ends can lose much of its benefit.
Upper floors are a separate question. A garden fence protects people in the garden and on the ground floor, but upstairs windows that can see over it get little benefit, so consultants consider building layout and glazing alongside the barrier.
The barrier itself must not leak
Height only works if little sound passes through the barrier. As a rule of thumb, the barrier's sound insulation (its DLR) should be around 10dB more than the reduction you need, and there must be no gaps at the base, joints, posts or ends. Acoustic reports and planning conditions often set a minimum surface mass for the same reason, such as 10kg/m² or 15kg/m².
NoiseBloc® Board & Batten (15.8kg/m², DLR 23dB road) and Premium TGV (22.4kg/m², DLR 26dB road, 28dB rail) are tested to the current standards, so you can check them against the report.
Planning permission
In England, a fence can usually be put up without planning permission up to 2m high, or 1m where it is next to a highway used by vehicles. Anything taller needs planning permission. On new developments that is normally covered by the scheme's consent, and the noise condition will say what the barrier must achieve. Rules differ in Scotland, Wales and Northern Ireland, and for listed buildings, so check with the local planning authority.
Taller means engineered
Wind load on a solid barrier grows quickly with height, and it is the wind, not the weight of the boards, that sizes the posts. Timber posts suit lower barriers on sheltered runs. Taller, exposed or end-of-run sections need steel posts: our indicative tables show 127×76×13 UB posts for a 2m barrier in standard wind, rising to 203×133×30 or heavier at 4m.
Every project needs a structural engineer's sign-off for posts and foundations. ATF can arrange a site-specific design on request. NoiseBloc® timber systems are supplied from 1.98m to 7m as standard, Eco from 1.8m to 4.5m.

