NoiseBlocNoiseBloc

Common acoustic fencing mistakes and how to avoid them

The same problems turn up on specifications and sites again and again. Most are easy to avoid if you know to look for them.

Or call 01264 366211, Monday to Friday

Short answer: The most common mistakes are specifying a closeboard or acoustic-style fence with no tested rating, relying on surface mass alone, leaving gaps at the base, ends and gates, quoting the wrong or an out-of-date rating, making the run too short, under-designing the posts and accepting an equivalent without evidence.

1. Specifying “acoustic closeboard”

We often see specifications and drawings call for an acoustic closeboard fence, or simply a close-boarded fence to a set height. Closeboard is a good privacy fence, but it is not designed or tested as an acoustic barrier. Featheredge boards overlap and are nailed to rails, and as the timber dries and moves, small gaps open between boards and at the base. Sound goes straight through them.

Avoid it: where the acoustic report asks for a barrier, specify a tested system, or a minimum DLR and surface mass with a gap-free, continuous construction. NoiseBloc® Board & Batten puts an acoustic cover strip over every joint, and Premium TGV uses interlocking tongue and groove boards, so they stay closed as the timber moves.

2. Specifying surface mass on its own

Many reports ask for a barrier of at least 10kg/m² or 15kg/m². Mass matters, but a heavy fence with gaps still leaks. A minimum mass with no requirement for a continuous, gap-free construction, or no tested rating, leaves the door open to fences that weigh enough on paper but underperform.

Avoid it: pair the minimum surface mass with a tested DLR and a gap-free construction. Board & Batten's tested sample is 15.8kg/m², so it meets both common minimums, with a tested rating behind it.

3. Gaps at the base, ends and gates

Sound finds the easiest path. The most common site faults are a gap under the bottom board, gravel boards that do not seal to the ground, steps on sloping ground left open, ends that stop short of a building or return, and gates with a large gap underneath.

Avoid it: keep the base board at finished ground level, step the fence in level bays on slopes and close each step, return or close the ends, and use matching acoustic gates with minimal gaps. Walk the line before handover.

4. Quoting the wrong rating

Specifications still ask for Category B3, which was withdrawn from the current edition of BS EN 1793-2, or quote a road rating where trains are the main source. Road and rail ratings use different noise spectra, so the same barrier can have different values.

Avoid it: state the DLR value and the standard edition, for example DLR not less than 25dB to BS EN 1793-2:2018, and add a rail rating to BS EN 16272-2:2023 where trains matter. Our guide to DLR and B3 explains more.

5. Treating the DLR as the noise reduction on site

A DLR rates the barrier construction in a laboratory. The reduction people hear depends mostly on the barrier's height, length and position. A high-rated barrier that is too low or too short will still disappoint.

Avoid it: let the acoustic consultant set the height, line and length from the noise model, then choose a barrier rated high enough that sound through it does not limit the result.

6. Runs that are too short or too low

Sound bends around the ends of a barrier as well as over the top. Runs that stop level with the end of a garden or a plant compound, or heights checked against gardens but not upstairs windows, leave obvious paths for the noise.

Avoid it: extend the barrier well past the ends of the source or the homes it protects, and check the line of sight to upper floors as well as gardens. Our height guide covers this.

7. Posts not designed for the height and wind

A solid acoustic barrier catches far more wind than an open fence. Standard fence posts and footings are often specified for barriers that need engineered posts, especially at height, on exposed sites and near free ends.

Avoid it: size posts and foundations for the barrier height, post centres and wind exposure. We publish indicative S355 steel post sizes in the technical library and can arrange a site-specific structural design.

8. Ignoring reflections

A reflective barrier sends sound back the other way. That matters where there are homes opposite, barriers on both sides of a road or railway, or plant screened on several sides.

Avoid it: specify an absorptive face where reflections matter, such as NoiseBloc® Eco absorptive (DLα 9dB, manufacturer's data).

9. Accepting an equivalent without evidence

“Or equivalent” substitutions are sometimes approved on a datasheet headline alone. The tested build may differ from what is supplied, the rating may be to an older standard, or there may be no band data for the consultant to check.

Avoid it: compare like with like: the same standard and edition, the same road or rail rating, band data, and a tested build that matches the supplied one. Our equivalent approved page sets out the checks.

10. Leaving the barrier until last

Barriers are often added after levels, drainage, services and landscaping are fixed. That leads to clashes, steps in the wrong places, rushed post design and cost surprises.

Avoid it: bring the barrier into the design early. Send us the acoustic report and a site plan and we will recommend a system, heights and post sizes, with a budget price within 2 working days.

FAQs

Questions we are asked most

Short, straight answers. Ask us anything else on 01264 366211.

Is a closeboard fence an acoustic fence?

Not on its own. Closeboard is designed for privacy, and small gaps open between the overlapping boards and at the base as the timber moves. Where an acoustic report asks for a barrier, use a tested, gap-free system such as NoiseBloc® Board & Batten or Premium TGV.

Is a 10kg/m² fence enough?

If that is what the acoustic report asks for, the barrier needs at least that surface mass and a continuous, gap-free construction. NoiseBloc® Board & Batten's tested sample is 15.8kg/m², so it meets both the 10kg/m² and 15kg/m² minimums that reports often set.

What should an acoustic fence specification include?

The height and line from the acoustic report, a minimum DLR to the current standard edition (and a rail rating where trains matter), a minimum surface mass, a requirement for gap-free construction with no gap at ground level, absorption where reflections matter, and posts designed for the height and wind exposure.

Specifying or pricing a barrier?

Send us the acoustic report or drawings. We will come back with a system, heights and post sizes to suit, and an approved installer if you need one.

Get a priceCall us
UKAS-accreditedlaboratory testing (timber systems)BS EN 1793-2road traffic noiseBS EN 16272-2railway noiseISO 9001quality managementISO 14001environmental managementFSC® and PEFCchain of custody timber available